.pdf File
CD Start Page DATA ACQUISITION ONLINE Page DATA ACQUISITION PRODUCTS Page

OM9 Series from $310
RMS AC Current and Voltage Transducers

 OM9 RMS AC Current and Voltage Transducers

The OM9 Series transducers convert ac currents and voltages to dc process signals for direct connection to data acquisition and recording systems. The OM9 employ true RMS measurement techniques in conditioning the ac signal. True RMS measurement provides accurate readings for signals which contain harmonic distortion. For measurement of currents and voltages greater than listed, the OM9 are directly compatible with OMEGA instrument transformers.

Specifications
Accuracy: 0.2% of Reading
Sustained Input Overrange: Voltage, 120% continuous,150% for 5 seconds; Current, 200% continuous, 1000% for 5 seconds
Outputs: 0 to 1 mA dc: into 10 KOhm 10 Vdc compliance;
4-20 mA into 750 Ohmn max 15 Vdc compliance
Zero Adjust: ▒5% minimum
Span Adjust: ▒10% minimum
Response Time:>400 msec 0-99% of full scale
Power Consumption: 5 VA max
Isolation: Input to output: 2500 Vac, 60 Hz, 1 min; Input to power: 2500 Vac, 60 Hz, 1 min; Input to case: 2500 Vac, 60 Hz, 1 min; Power to output: 2000 Vac, 60 Hz, 1 min;
Power to case: 2000 Vac, 60 Hz, 1 min; Output to case: 500 Vac, 60 Hz, 1 min
Dimensions: 12 H x 13.3 W x 9.6 cm D (4.717" x 5.236" x 3.769")


VIEW an Adobe Acrobat pdf file for more product info (requires Acrobat Reader).


Sales and Service 1.800.826.6342
U.S.A. and Canada
International Callers;
Sales and Service; 203.359.1660
Please E-Mail any comments or suggestions to OMEGA®.
www.omega.com
® COPYRIGHT 1999 OMEGA ENGINEERING, INC.